1. Fan set to On
With the fan on On, the blower runs between heat cycles and pushes room-temperature air. Set it to Auto and see if warm air returns during heating.
2. Furnace just started
The blower may start a little before the heat exchanger is fully warm. A minute of cool air at the start of a cycle is normal.
3. Dirty flame sensor
Burners light for a few seconds, then shut off, and the furnace retries. This is very common in Solano County, where furnaces sit unused through a long, hot summer and dust settles on the sensor.

4. Failed igniter
You hear the small inducer fan start but never see the orange glow or the flame. After a few tries the furnace locks out and the blower may keep running.
5. Overheating from a clogged filter
The limit switch shuts off the burners to protect the heat exchanger, but the blower keeps running to cool it, which feels like cold air. Replace the filter and open all vents.
6. Heat pump, not a furnace
If your outdoor unit runs in winter, you have a heat pump. Brief cool air during defrost is normal. See heat pump not heating.
Stop and call if
you smell gas or burning plastic, see scorch marks or sparks, a carbon monoxide alarm sounds, or a breaker trips a second time. For gas or CO: leave the house and call 9-1-1, then PG&E at 1-800-743-5000.