The five-minute check
- Thermostat: on Heat, set 3°F above room temperature, screen not blank (replace batteries).
- Service switch: a light-switch near the furnace or on the closet wall. Someone may have flipped it off thinking it was a light.
- Breaker: labeled furnace, FAU or air handler. Reset once.
- Door: the lower panel presses a safety switch. If it's loose, the furnace won't run.
- Condensate: on attic and closet units with AC coils, a full pan or tripped float switch can cut power to the whole system.
Look for a blinking light
Most modern furnaces have a small LED visible through a window in the lower door. A blinking pattern is a diagnostic code; the legend is usually on a label inside the door. Note the pattern and tell the technician.
After a power outage
PG&E outages and shutoffs can leave a furnace dead even after power returns: a tripped breaker, a thermostat that lost settings, or a control board fuse blown by a surge. Check the breaker and thermostat first.
Stop and call if
you smell gas or burning plastic, see scorch marks or sparks, a carbon monoxide alarm sounds, or a breaker trips a second time. For gas or CO: leave the house and call 9-1-1, then PG&E at 1-800-743-5000.