Silent outdoor unit
- Thermostat on Cool and set below room temperature.
- Outdoor disconnect (the grey box on the wall near the unit): make sure it's on or the pull-out block is seated.
- Breaker panel: look for a tripped double breaker labeled AC or condenser. Reset once.
- Some systems shut the condenser off when the indoor drain pan is full. Check the condensate switch.
If it's still silent, the contactor, low-voltage wiring, or a thermostat/control issue is likely.
Humming but not starting
A hum with no fan movement usually means the capacitor that helps the motor and compressor start has failed. After several 100°F days, weak capacitors finally quit, which is why this call spikes during Solano County heat waves. A failed fan motor or a seized compressor can sound the same. Leave it off: a humming compressor that can't start overheats.
Stop and call if
you smell gas or burning plastic, see scorch marks or sparks, a carbon monoxide alarm sounds, or a breaker trips a second time. For gas or CO: leave the house and call 9-1-1, then PG&E at 1-800-743-5000.
Fan spins, but the unit shuts off after a few minutes
That pattern points to overheating (dirty coil, failing fan motor), a high-pressure safety trip, or a compressor struggling to stay running. Clear around the unit and rinse the coil with the power off; if it continues, call.